Skip to main content

Design Parameters

The following parameters are exemplary for 35μm copper thickness.
For other thicknesses / special production, please contact our technical hotline: +49 (0)8104 628 210.

* Prior data check necessary. ** see Buried Via, Blind Via
IndexStandard (min.)Special production(min.)
A, B, CVia, buried via



Component hole:
Annular ring circular + 25µm
aspect ratio
diameter
via pad
annular ring
1:10
200µm
400µm
100µm circular
1:12
150µm
330µm
90µm circular
DBlind Via, mechanical
max. Ø 300µm
aspect ratio
diameter
via pad
annular ring
1:1
200µm
400µm
100µm circular
1:1.2
150µm
350µm
100µm circular
EBlind Via, laseraspect ratio
diameter
via pad
annular ring
-
-
-
-
1:1
100µm
280µm
90µm circular*
FStacked Vias
Disproportional high effort. Please contact our CAM department for alternatives.
aspect ratio
diameter
via pad
annular ring
-
-
-
-
-
-
-
-
GStaggered Viasaspect ratio
diameter
via pad
annular ring
1:1 - 1:12 **
200µm
400µm
100µm circular
1:1 - 1:12 **
100µm
300µm
90µm circular
H, IConductors
(see Conductor/copper thickness)
width
space
100µm
100µm
75µm | 90µm
100µm | 90µm
JConductor/pad to milling edge
Conductor/pad to scoring edge
space200µm
500µm
200µm
500µm
KConductor/pad to hole (PTH, NPTH)space200µm200µm
LSolder-stop, greenclearance
bridge
50µm circular
100µm
25µm circ. (BGA)
80µm
Solder-stop, other colorsclearance
bridge
-
-
50µm circular
125µm